







Stay comfortable year-round with the Goodman 1.5 Ton 14.5 SEER2 R-32 40,000 BTU 80% AFUE Dual Fuel System - Upflow, which seamlessly integrates a high-efficiency heat pump with a reliable gas furnace, ensuring optimal performance in both heating and cooling seasons.
Key Features of the 1.5 Ton 14.5 SEER2 R-32 Dual Fuel System:
- High-Efficiency Scroll Compressor: Delivers consistent performance with lower energy consumption.
- SmartShift™ Technology: Ensures quiet and reliable defrost cycles for improved efficiency.
- Enhanced Aluminum Fin Coil: Goodman Dual Fuel System provides superior heat transfer and durability.
- Factory-Installed Components: Includes a filter drier, accumulator, crankcase heater, and muffler to enhance longevity and performance.
- Safety Features: High/low-pressure switches protect against unsafe pressure conditions.
- Durable Construction: Steel louver coil guard and sweat connection service valves for easier maintenance.
Evaporator Coil - CAPTA2422A3:
- All-Aluminum Coil: Optimized for R-32 refrigerant for maximum efficiency and corrosion resistance.
- Factory-Installed TXV (Thermal Expansion Valve): Provides precise refrigerant flow for improved system efficiency.
- Compact & Versatile Design: Designed for attic and tight-space installations with improved accessibility.
- UV-Resistant & Rust-Proof Drain Pan: Goodman Dual Fuel System prevents water retention and structural damage.
- Certified for Performance & Safety: AHRI Certified and ETL Listed.
Gas Furnace - GR9S800403AN:
- High-Efficiency Heating: 80% AFUE rating for cost-effective gas heating.
- Durable Aluminized-Steel Heat Exchanger: Designed for long-lasting reliability.
- Single-Stage Gas Valve: 1.5 Ton 14.5 SEER2 provides consistent heating performance.
- Multi-Speed Blower Motor: Moreover, it delivers quiet and efficient airflow.
- Self-Diagnostic Control Board: Continuously monitors system operation for easy troubleshooting.
- Flexible Installation Options: Lastly, it supports upflow and horizontal configurations for adaptable placement.
In summary, the Goodman 1.5 Ton 14.5 SEER2 R-32 Dual Fuel System - Upflow offers the perfect balance of efficiency, reliability, and flexibility. Whether it's the peak of summer or the coldest winter night, this system ensures consistent indoor comfort with its advanced heat pump technology and high-performance gas furnace.
-
AHRI Reference 215218578 Heat Pump Condenser Model Number GLZS4BA1810 SEER 2 14.3 EER2 12.5 Tonnage 1.5 Unit Height x Width x Depth 32.5 x 26 x 29 in Unit Weight 150 lb Cooling Capacity 18,000 Btu/H Heating Capacity 18,000 Btu/H Power Voltage 208/230 V Phase Single Motor Type PSC Min Circuit Amps 11.2 Max Fuse Size 15 Liquid Connection 3/8" Suction Fitting 3/4" Refrigerant Type R-32 Evaporator Coil Model Number CAPTA2422A3 Tonnage 2 Unit Height x Width x Depth 22 x 14 x 21 in Cased/Uncased Cased Coil Application Upflow/Downflow Refrigerant Type R-32 Gas Furnace Model Number GR9S800403AN Height x Width x Depth 33-3/8 x 14 x 28 in Weight 86 lb AFEU 80% Configuration Upflow/Horizontal BtuH Input 40,000 BtuH Output 32,000 Tons 3 CFM 1,200 Min. Circuit Amps 7.7 Vent Size 4" Motor Type ECM Stages Single LoNox No -
-
Processing Time
We process and ship orders Monday through Friday. Orders placed by 12 p.m. EST on these days are usually shipped within 1 to 2 business days and arrive within 3 to 5 business days. Orders placed on weekends will start processing the next business day. Some items may be backordered, leading to possible delays. Shipping times begin once the order leaves our warehouse. While we aim for timely delivery, delays by freight or ground carriers are beyond our control. FREE Life Gate.
Equipment Arrival
Shipping times are not guaranteed and may vary by address. Upon delivery, inspect each item and match the count with the delivery receipt before signing. Report any missing or incorrect items within 24 hours; claims reported after this period may be denied. Inspect items for damage in front of the driver before signing the receipt. Note any issues like dents or scratches clearly on the receipt or reject the shipment if damaged.
Making Notes on the Delivery Receipt
If the items and quantity on the delivery receipt match what you received and are undamaged, sign and mark the receipt as "Clear."
If items or boxes are missing, mark the receipt as " Short" and list the missing items. A packing slip will be attached for reference. Allow up to 7 business days for the carrier to find the missing items. If they cannot be located, we will ship replacements to you at no extra charge. If the strip wrap is torn or replaced, mark the receipt as "Wrap Broken."
How Do I Handle a Damaged Shipment?
If any items are damaged, mark the receipt as "Damaged," specifying the items and the nature of the damage. Refuse only the damaged items, keep and sign for the rest, and clearly note the refused items on the receipt. Contact our Customer Service to report which items were refused and which were accepted. We will ship replacements once our Shipping Department confirms the damage with the Freight LTL Company. If you sign for the delivery but later discover damage, you are responsible for it. You will need to contact the Freight LTL Company’s claims department directly to file a claim.