Skip to product information
1 of 8

Model: GLZS4BA1810 / CAPTA3022A3 / GR9S800403AN

1.5 Ton 14.5 SEER2 R-32 40,000 Btu 80% Afue Goodman Dual Fuel System - Upflow

1.5 Ton 14.5 SEER2 R-32 40,000 Btu 80% Afue Goodman Dual Fuel System - Upflow

Free Liftgate Shipping 10 Year parts warranty W/ online registration

Heat Pump & furnace combo: Pre-charged HP to 15ft w/ 14" furnace. Natural gas/propane (kit req).
Regular price $4,065.00
Regular price Sale price $4,065.00
Sale Sold out
Guaranteed Safe Checkout

Free express shipping
Ships in 1-2 business days
60 Days return policy
Expert Support

Price Match Request

Found a lower price on equipment? Let us know and we'll match it (Exclude below-cost items).

Product
1.5 Ton 14.5 SEER2 R-32 40,000 Btu 80% Afue Goodman Dual Fuel System - Upflow
Our Price
$4,065.00

Got a question? Talk with our experts anytime

Call Us at 866-718-1799

CHAT WITH US EMAIL US

Product Details

Enjoy unmatched comfort and energy savings with the Goodman 40,000 Btu 80% Afue 1.5 Ton 14.5 SEER2 R-32 Dual Fuel System. Moreover, this intelligent system seamlessly integrates heat pump and gas furnace technology for optimal efficiency and year-round comfort.

Key Features of the 1.5 Ton 14.5 SEER2 R-32:

  • High Efficiency: Meets 2023 M1 Test Standards.
  • Safety: Removable grille style top design compliant with UL 60335-2-40.
  • Protection: Steel louver coil guard.
  • Durability: Heavy-gauge galvanized-steel cabinet with 500-hour salt-spray approved finish.
  • Serviceability: Top and side maintenance access.
  • Hurricane Resistance: Meets 2023 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available).

Evaporator Coil - CAPTA3022A3:

  • All-Aluminum Coil: Durable and efficient heat transfer.
  • R-32 Optimized: Designed for use with R-32 refrigerant, thus improving efficiency.   
  • Factory-Installed TXVs: Consequently, for precise refrigerant control in cooling and heating modes.
  • Standardized Suction Tube: Hence, simplifying installation and service.
  • Check Flowrator: Goodman Dual Fuel System monitors and ensures proper refrigerant flow.
  • Upflow/Downflow Installation: Ideal for attic installations with convenient access.
  • Single Front Access: Easy access for service and maintenance.
  • Reduced Condensation: Minimizes moisture buildup within the cabinet.
  • Durable Finish: Resists corrosion and enhances appearance.
  • Rust-Resistant Drain Pan: Durable and long-lasting, additionally with features to minimize water buildup and prevent leaks.
  • Easy Coil Removal: Allows for easy maintenance and service without disrupting the unit's structure.
  • UV Resistant Drain Pan: Maintains its appearance and functionality even with prolonged sun exposure.
  • Certified: Meets industry standards for safety, performance, and efficiency.

Gas Furnace - GR9S800403AN:

  • High Reliability & Quality: Engineered for dependable and long-lasting performance.
  • Durable Igniter: Ensures consistent ignition and extends the life of the igniter.
  • Versatility: Provisions for electronic air cleaner and humidifier, consequently for enhanced indoor air quality.
  • Energy Efficient & Quiet: Efficient operation with minimal noise disturbance.
  • Self-Diagnostic Control Board: Easy troubleshooting and maintenance with constant memory for fault history.
  • Easy Installation & Setup: Quick and hassle-free installation process.
  • Quiet & Simple Operation: User-friendly controls, thus providing easy operation.

Enhance your home's coziness with the Goodman 40,000 Btu 80% AFUE 1.5 Ton 14.5 SEER2 R-32 Dual Fuel System. Additionally, explore flexible financing and receive a complimentary quote. Schedule your installation today for a seamless experience.

Specifications

AHRI Reference 215218590
Heat Pump Condenser Model Number GLZS4BA1810
SEER 2 14.3
EER2 12.5
Tonnage 1.5
Unit Height x Width x Depth 32.5 x 29 x 29 in
Unit Weight 150 lb
Cooling Capacity 18,000 Btu/H
Heating Capacity 18,000 Btu/H
Power Voltage 208/230 V
Phase Single
Motor Type PSC
Min Circuit Amps 11.2
Max Fuse Size 15
Liquid Connection 3/8"
Suction Fitting 3/4"
Refrigerant Type R-32
Evaporator Coil Model Number CAPTA3022A3
Tonnage 2.5
Unit Height x Width x Depth 22 x 14 x 21 in
Weight 37 lb
Cased/Uncased Cased
Coil Application Upflow/Downflow
Refrigerant Type R-32
Gas Furnace Model Number GR9S800403AN
Height x Width x Depth 33-3/8 x 14 x 28 in
Weight 86 lb
AFEU 80%
Configuration Upflow/Horizontal
BtuH Input 40,000
BtuH Output 32,000
Tons 3
CFM 1,200
Min. Circuit Amps 7.7
Vent Size 4"
Motor Type ECM
Stages Single
LoNox No

Warranty & Shipping

Warranty 

Enjoy a 10-year limited parts warranty when your unit is registered within 60 days of installation. The installation must be completed by a properly certified professional adhering to city, state and federal laws.

Processing Time

We process and ship orders Monday through Friday. Orders placed by 12 p.m. EST on these days are usually shipped within 1 to 2 business days and arrive within 3 to 5 business days. Orders placed on weekends will start processing the next business day. Some items may be backordered, leading to possible delays. Shipping times begin once the order leaves our warehouse. While we aim for timely delivery, delays by freight or ground carriers are beyond our control. FREE Life Gate. 

Equipment Arrival

Shipping times are not guaranteed and may vary by address. Upon delivery, inspect each item and match the count with the delivery receipt before signing. Report any missing or incorrect items within 24 hours; claims reported after this period may be denied. Inspect items for damage in front of the driver before signing the receipt. Note any issues like dents or scratches clearly on the receipt or reject the shipment if damaged.

Making Notes on the Delivery Receipt

If the items and quantity on the delivery receipt match what you received and are undamaged, sign and mark the receipt as "Clear."

If items or boxes are missing, mark the receipt as " Short" and list the missing items. We will ship replacements to you at no extra charge. If the strip wrap is torn or replaced, mark the receipt as "Wrap Broken."

How Do I Handle a Damaged Shipment?

If  any items are damaged, mark the receipt as "Damaged," specifying the items and the nature of the damage. Refuse only the damaged items, keep and sign for the rest, and clearly note the refused items on the receipt. Contact our Customer Service to report which items were refused and which were accepted. We will ship replacements once our Shipping Department confirms the damage with the Freight LTL Company. If you sign for the delivery but later discover damage, you are responsible for it. You will need to contact the Freight LTL Company’s claims department directly to file a claim.

Add Accessories

View full details

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

You Might Also Like