Skip to product information
1 of 3

Goodman

SKU: Model: GLZS4BA4810 / AMST48CU1300

4 Ton 15.2 SEER2 Goodman R32 Heat Pump Split System

4 Ton 15.2 SEER2 Goodman R32 Heat Pump Split System

Regular price $4,912.00
Regular price Sale price $4,912.00
Sale Sold out
Guaranteed Safe Checkout
View full details
  • Upgrade your HVAC system with the efficient and reliable Goodman 4 Ton 15.2 SEER2 Heat Pump Split System. Designed to meet 2023 M1 test standards, this system provides year-round comfort for your home with superior performance

    Benefits of Heat Pump Split System:

    4 Ton Heat Pump Condenser (GLZS4BA4810):

    • Designed to meet 2023 M1 Test Standards, hence providing energy efficiency and environmental compliance.
    • Energy-efficient and quiet operation, thus perfect for both residential and commercial spaces.
    • Versatile system providing both heating and cooling with options for 5, 6, 8, or 10 kW heating.
    • Heavy-gauge galvanized-steel cabinet for durability, with a steel louver coil guard for added protection.
    • Corrosion-resistant Architectural Gray powder-coat finish, salt-spray approved for up to 500 hours, ideal for coastal areas.
    • Removable grille-style top for easy maintenance and accessibility, compliant with UL 60335-2-40 standards.
    • Weather-resistant and this heat pump split system meets 2023 Florida Building Code for hurricane-type winds when anchored.

    4 Ton Air Handler (AMST48CU1300):

    • All-aluminum tube/aluminum fin coil, thus provides optimal heat transfer and long-lasting performance.
    • Direct-drive, 9-speed ECM motor enhances efficiency and operates quietly.
    • Durable galvanized-steel body with a rigid SmartFrame cabinet, consequently for structural integrity and easy access.
    • Can be installed horizontally or vertically, with a 21” depth ideal for attic installations.
    • Factory-installed pull-type disconnect, primary/secondary drain connection, and DecaBDE-free thermoplastic drain pan, hence giving easy maintenance.
    • Designed to minimize noise for a comfortable environment.
    • Tool-less filter access and screw-less sides/back to reduce condensation, ideal for humid areas.
    • Foil-faced insulation helps reduce condensation in high-humidity settings.
    • This heat pump split system is AHRI Certified & ETL Listed for reliability and energy savings.

    Improve your home's comfort with the Goodman 4 Ton 15.2 SEER2 Heat Pump Split System. Advanced features, easy installation, and a corrosion-resistant finish ensure reliable, efficient, and long-lasting performance.

  • AHRI 215213861
    Heat Pump Model Number GLZS4BA4810
    Unit Height 36.5 in
    Unit Width 35.5 in
    Unit Depth 35.5 in
    Unit Weight 269 lb
    SEER 2 15.2
    Heating Capacity Nominal 48000 Btu/H
    Max Overcurrent Protection 40 A
    Power Phase 1 Ph
    Power Voltage 208/230 V
    Compressor Stages Single Stage
    Compressor Type Scroll
    Refrigerant Type R-32
    Air Handler Model Number AMST48CU1300
    Unit Height 58 in
    Unit Width 21.125 in
    Unit Depth 21 in
    Unit Weight 153 lb
    Tonnage 4
    Cooling Capacity Nominal 48000 Btu/H
    Max Overcurrent Protection 15 A
    Power Phase 1 Ph
    Power Voltage 208/230 V
    Case/Uncased Cased
    Energy Source Electric
    Motor Speed Type Nine Speed ECM
    Refrigerant Type R-32
  • Processing Time

    We process and ship orders Monday through Friday. Orders placed by 12 p.m. EST on these days are usually shipped within 1 to 2 business days and arrive within 3 to 5 business days. Orders placed on weekends will start processing the next business day. Some items may be backordered, leading to possible delays. Shipping times begin once the order leaves our warehouse. While we aim for timely delivery, delays by freight or ground carriers are beyond our control. FREE Life Gate. 

    Equipment Arrival

    Shipping times are not guaranteed and may vary by address. Upon delivery, inspect each item and match the count with the delivery receipt before signing. Report any missing or incorrect items within 24 hours; claims reported after this period may be denied. Inspect items for damage in front of the driver before signing the receipt. Note any issues like dents or scratches clearly on the receipt or reject the shipment if damaged.

    Making Notes on the Delivery Receipt

    If the items and quantity on the delivery receipt match what you received and are undamaged, sign and mark the receipt as "Clear."

    If items or boxes are missing, mark the receipt as " Short" and list the missing items. A packing slip will be attached for reference. Allow up to 7 business days for the carrier to find the missing items. If they cannot be located, we will ship replacements to you at no extra charge. If the strip wrap is torn or replaced, mark the receipt as "Wrap Broken."

    How Do I Handle a Damaged Shipment?

    If  any items are damaged, mark the receipt as "Damaged," specifying the items and the nature of the damage. Refuse only the damaged items, keep and sign for the rest, and clearly note the refused items on the receipt. Contact our Customer Service to report which items were refused and which were accepted. We will ship replacements once our Shipping Department confirms the damage with the Freight LTL Company. If you sign for the delivery but later discover damage, you are responsible for it. You will need to contact the Freight LTL Company’s claims department directly to file a claim.

  • Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)