The Goodman 2 Ton 14 SEER2 96% AFUE 80,000 BTU Gas Furnace & R32 Air Conditioner - Upflow offers exceptional energy efficiency, durability, and reliability, ensuring year-round comfort for your home.
Key Features of the Goodman 2 Ton 14 SEER2 96% AFUE:
- Efficient Cooling: Equipped with a high-performance, energy-efficient compressor pre-charged for 15 feet of tubing.
- Durable Design: Copper tubing with enhanced aluminum fin coil ensures superior heat transfer and longevity.
- User-Friendly Maintenance: In addition, Goodman 2 Ton 14 SEER2 96% features factory-installed filter drier and accessible sweat connection service valves.
- Certifications: Moreover, AHRI and ETL certified for reliable and safe operation.
Cabinet Features of the Goodman 2 Ton 14 SEER2 96%:
- Venturi design improves airflow velocity for maximum cooling.
- Corrosion-resistant powder-paint finish passes 500-hour salt-spray tests.
- Sturdy steel louver coil guard and accessible panels enhance durability and serviceability.
Evaporator Coil - CAPTA2422B3:
- Refrigerant Optimized: Designed for R-32 refrigerant with factory-installed thermal expansion valves.
- Compact Build: Goodman 2 Ton 14 SEER2 96% slim 21-inch depth suits tight attic spaces and horizontal installations.
- Reliable Drainage: Rust- and UV-resistant thermoplastic drain pan minimizes water retention.
- Certified Performance: Additionally, AHRI and ETL certifications guarantee high-quality performance.
Gas Furnace - GM9C960803BN:
- Efficient Heating: Furthermore, it achieves a 96% AFUE rating for consistent warmth and lower energy costs.
- Long-Lasting Design: Additionally, features a durable igniter and provisions for air cleaners and humidifiers.
- Smart Diagnostics: Self-diagnostic control board ensures smooth operation and easy troubleshooting.
- Quiet and Flexible: Lastly, Goodman 2 Ton 14 SEER2 96% operates quietly and supports versatile installation options for upflow or horizontal setups.
In conclusion, the Goodman 2 Ton 14 SEER2 96% AFUE 80,000 BTU Gas Furnace & R32 Air Conditioner - Upflow combines innovative technology, energy savings, and user-friendly features, making it an ideal solution for your home's heating and cooling needs.
-
AHRI Reference 215327486 AC Model Number GLXS3BN2410 SEER 2 13.4 Unit Height 27.5 in Unit Width 26 in Unit Depth 26 in Unit Weight 114 lb Cooling Capacity Nominal 24,000 Btu/H Max Overcurrent Protection 15A Power Voltage 208/230 V Compressor Stages Single Stage Compressor Type Rotary Refrigerant Type R-32 Evaporator Coil Model Number CAPTA2422B3 Tonnage 2 Unit Height 22 in Unit Width 17.5 in Unit Depth 21 in Cased/Uncased Cased Coil Application Upflow/Downflow Refrigerant Type R-32 Gas Furnace Model Number GM9C960803BN AFUE 96% Unit Height 33.375 in Unit Width 17.5 in Unit Depth 28 in Unit Weight 118 lb Cooling Capacity Nominal 36,000 Btu/H Max Overcurrent Protection 15 A Installation Configuration Upflow/Horizontal Power Voltage 115 V Motor Speed Type Nine Speed ECM -
-
Processing Time
We process and ship orders Monday through Friday. Orders placed by 12 p.m. EST on these days are usually shipped within 1 to 2 business days and arrive within 3 to 5 business days. Orders placed on weekends will start processing the next business day. Some items may be backordered, leading to possible delays. Shipping times begin once the order leaves our warehouse. While we aim for timely delivery, delays by freight or ground carriers are beyond our control. FREE Life Gate.
Equipment Arrival
Shipping times are not guaranteed and may vary by address. Upon delivery, inspect each item and match the count with the delivery receipt before signing. Report any missing or incorrect items within 24 hours; claims reported after this period may be denied. Inspect items for damage in front of the driver before signing the receipt. Note any issues like dents or scratches clearly on the receipt or reject the shipment if damaged.
Making Notes on the Delivery Receipt
If the items and quantity on the delivery receipt match what you received and are undamaged, sign and mark the receipt as "Clear."
If items or boxes are missing, mark the receipt as " Short" and list the missing items. A packing slip will be attached for reference. Allow up to 7 business days for the carrier to find the missing items. If they cannot be located, we will ship replacements to you at no extra charge. If the strip wrap is torn or replaced, mark the receipt as "Wrap Broken."
How Do I Handle a Damaged Shipment?
If any items are damaged, mark the receipt as "Damaged," specifying the items and the nature of the damage. Refuse only the damaged items, keep and sign for the rest, and clearly note the refused items on the receipt. Contact our Customer Service to report which items were refused and which were accepted. We will ship replacements once our Shipping Department confirms the damage with the Freight LTL Company. If you sign for the delivery but later discover damage, you are responsible for it. You will need to contact the Freight LTL Company’s claims department directly to file a claim.