The Goodman 2 Ton 14 SEER2 AC & 80% AFUE 60K BTU Gas Furnace System, R32 Refrigerant - Upflow combines energy efficiency and reliability to provide year-round comfort with cutting-edge features for both heating and cooling needs.
Product Features of the Goodman 2 Ton 14 SEER2 AC:
- Energy-Efficient Compressor: Furthermore, fully charged for 15' of tubing, ensuring optimal cooling with minimal energy use.
- Durable Construction: Copper tube and enhanced aluminum fin coil (5mm diameter) for maximum heat transfer.
- Maintenance-Friendly: Factory-installed filter drier, sweat connection service valves for easy access, and enclosed contactor with lug connection.
- Certified Quality: AHRI and ETL certifications for performance and safety.
Cabinet Features of the Goodman 2 Ton 14 SEER2:
- Increased Airflow Efficiency: Venturi design enhances airflow velocity.
- Corrosion Resistance: Architectural Gray powder-coat finish with 500-hour salt-spray approval.
- Easy Maintenance: Removable grille-style top with top and side access for simple service.
Evaporator Coil (CAPTA3022B3):
- R-32 Refrigerant Compatibility: Optimized for R-32 refrigerant with circuits and manifolds designed for maximum efficiency.
- Long-Lasting Performance: Also, R-32 sensor designed to extend the coil's lifespan.
- Efficient Drainage: Features a UV-resistant, rust-resistant, and low water-retention thermoplastic drain pan.
- Space-Efficient: Goodman 2 Ton 14 SEER2 AC 21" depth for easy attic access with a single front access panel for maintenance.
- Certified Performance: Additionally, AHRI and ETL listed for reliability and quality.
Gas Furnace (GR9S800603BN):
- High Efficiency: 80% AFUE ensures energy savings while delivering consistent warmth.
- Quiet and Efficient Heating: Designed for quieter operation and energy-efficient circulation.
- Long-Lasting Durability: Durable construction and long igniter life for dependable performance.
- Eco-Friendly: In addition, lower NOx emissions for better environmental impact.
- Convenient Controls: Self-diagnostic control board with constant memory for easier troubleshooting.
- Versatile: Operates on single-stage or two-stage thermostats, and is compatible with electronic air cleaners and humidifiers.
Cabinet Features:
- Multi-Position Installation: Suitable for upflow, horizontal left or right installation.
- Flexible Venting Options: Certified for direct vent (2-pipe) or non-direct vent (1-pipe) with optional side venting.
- Efficient Design: Less than 2% air leakage (Qleak), fully insulated heat exchanger, and blower section for improved efficiency.
Therefore, the Goodman 2 Ton 14 SEER2 AC & 80% AFUE 60K BTU Gas Furnace System, R32 Refrigerant - Upflow offers a blend of energy efficiency, ease of installation, and long-lasting reliability, making it the ideal solution for your heating and cooling needs. Overall, with its high-quality components, certification compliance, and environmentally-friendly design, this system provides comfort and savings in a reliable package.
-
AHRI Reference 215277047 AC Model Number GLXS3BN2410 SEER 2 13.4 Tonnage 2 Unit Height x Width x Depth 27.5 x 26 x 26 in Unit Weight 114 lb Cooling Capacity Nominal 24,000 Btu/H Max Overcurrent Protection 15A Power Voltage 208/230 V Compressor Stages Single Stage Compressor Type Rotary Refrigerant Type R-32 Evaporator Coil Model Number CAPTA3022B3 Tonnage 2.5 Unit Height x Width x Depth 22 x 17.5 x 21 in Cased/Uncased Cased Coil Application Upflow/Downflow Refrigerant Type R-32 Gas Furnace Model Number GR9S800603BN Height x Width x Depth 33-3/8 x 17.5 x 28 in Weight 100 lb AFEU 80% Configuration Upflow/Horizontal BtuH Input 60,000 BtuH Output 48,000 Tons 3 CFM 1,200 Min. Circuit Amps 7.7 Motor Type ECM Stages Single LoNox No -
-
Processing Time
We process and ship orders Monday through Friday. Orders placed by 12 p.m. EST on these days are usually shipped within 1 to 2 business days and arrive within 3 to 5 business days. Orders placed on weekends will start processing the next business day. Some items may be backordered, leading to possible delays. Shipping times begin once the order leaves our warehouse. While we aim for timely delivery, delays by freight or ground carriers are beyond our control. FREE Life Gate.
Equipment Arrival
Shipping times are not guaranteed and may vary by address. Upon delivery, inspect each item and match the count with the delivery receipt before signing. Report any missing or incorrect items within 24 hours; claims reported after this period may be denied. Inspect items for damage in front of the driver before signing the receipt. Note any issues like dents or scratches clearly on the receipt or reject the shipment if damaged.
Making Notes on the Delivery Receipt
If the items and quantity on the delivery receipt match what you received and are undamaged, sign and mark the receipt as "Clear."
If items or boxes are missing, mark the receipt as " Short" and list the missing items. A packing slip will be attached for reference. Allow up to 7 business days for the carrier to find the missing items. If they cannot be located, we will ship replacements to you at no extra charge. If the strip wrap is torn or replaced, mark the receipt as "Wrap Broken."
How Do I Handle a Damaged Shipment?
If any items are damaged, mark the receipt as "Damaged," specifying the items and the nature of the damage. Refuse only the damaged items, keep and sign for the rest, and clearly note the refused items on the receipt. Contact our Customer Service to report which items were refused and which were accepted. We will ship replacements once our Shipping Department confirms the damage with the Freight LTL Company. If you sign for the delivery but later discover damage, you are responsible for it. You will need to contact the Freight LTL Company’s claims department directly to file a claim.