The Goodman 3.5 Ton 13.8 SEER2 AC & 80% AFUE 80K BTU Gas Furnace System, R32 Refrigerant - Upflow (GLXS3BN4210) is engineered for efficiency and long-lasting performance. It incorporates eco-friendly R32 refrigerant for optimal comfort while reducing energy consumption.
Product Benefits of the Goodman 3.5 Ton 13.8 SEER2 AC:
- Energy-Efficient Compressor: Pre-charged for 15' of tubing length, ensuring excellent performance.
- Durability: Furthermore, it features copper tubing with an enhanced aluminum fin coil (5mm diameter) for superior heat transfer.
- Convenience: Factory-installed filter drier, high-pressure switch, and easy-access service valves simplify maintenance.
- Certifications: Additionally, AHRI Certified and ETL Listed, guaranteeing top-tier performance and safety.
Cabinet Features of the Goodman 3.5 Ton 13.8 SEER2:
- Design: Removable grille-style top compliant with UL 60335-2-40 for easy maintenance.
- Airflow: Venturi for increased velocity and efficiency.
- Durability: Architectural Gray powder-coat finish with 500-hour salt-spray approval for long-lasting exterior.
- Access: Top and side maintenance access with single-panel control access for field-installed accessories.
- Condensate Drainage: Faster condensate drainage and no leakage, ensuring optimal system performance.
- Tax Credit: Moreover, Goodman 3.5 Ton 13.8 SEER2 is eligible for tax credits.
- Installation: Multi-position installation (upflow, horizontal left or right) with certified direct venting (2-pipe) or non-direct venting (1-pipe).
- Energy-Efficiency: Quiet and energy-efficient circulation with a self-diagnostic control board and low cabinet air leakage (Qleak ≤ 2%).
Evaporator Coil - CAPFA4226B3:
- Material: Also, all-aluminum coil optimized for R32 refrigerant with thermal expansion valves for increased efficiency.
- Compact Design: 21" depth for easier attic installation with a single front access panel.
- Durability: Rust-resistant, UV-protected thermoplastic drain pan with low water retention design.
Gas Furnace - GR9S800804BN:
- Efficiency: Additionally, 80% AFUE for cost-effective heating and reduced NOx emissions.
- Reliability: Long igniter life with durable components for dependable operation.
- Versatility: Goodman 3.5 Ton 13.8 SEER2 supports single- or two-stage thermostats and integrates seamlessly with electronic air cleaners and humidifiers.
Therefore, the Goodman 3.5 Ton 13.8 SEER2 AC & 80% AFUE 80K BTU Gas Furnace System is an ideal solution for homeowners seeking reliable and energy-efficient heating and cooling. Overall, its advanced features and eco-friendly refrigerant ensure long-term comfort and significant energy savings.
-
AHRI Reference 215277629 AC Model Number GLXS3BN4210 SEER 2 13.4 Tonnage 3.5 Unit Height x Width x Depth 35.75 x 29 x 29 in Unit Weight 180 lb Cooling Capacity Nominal 42,000 Btu/H Max Overcurrent Protection 30A Power Voltage 208/230 V Compressor Stages Single Stage Compressor Type Scroll Refrigerant Type R-32 Evaporator Coil Model Number CAPTA4230C3 Tonnage 3.5 Unit Height x Width x Depth 30 x 21 x 21 in Cased/Uncased Cased Coil Application Upflow/Downflow Refrigerant Type R-32 Gas Furnace Model Number GR9S800804CN Height x Width x Depth 33-3/8 x 21 x 28 in Weight 132 lb AFEU 80% Configuration Upflow/Horizontal BtuH Input 80,000 BtuH Output 64,000 Tons 4 CFM 1,600 Min. Circuit Amps 11.3 Motor Type ECM Stages Single LoNox No -
-
Processing Time
We process and ship orders Monday through Friday. Orders placed by 12 p.m. EST on these days are usually shipped within 1 to 2 business days and arrive within 3 to 5 business days. Orders placed on weekends will start processing the next business day. Some items may be backordered, leading to possible delays. Shipping times begin once the order leaves our warehouse. While we aim for timely delivery, delays by freight or ground carriers are beyond our control. FREE Life Gate.
Equipment Arrival
Shipping times are not guaranteed and may vary by address. Upon delivery, inspect each item and match the count with the delivery receipt before signing. Report any missing or incorrect items within 24 hours; claims reported after this period may be denied. Inspect items for damage in front of the driver before signing the receipt. Note any issues like dents or scratches clearly on the receipt or reject the shipment if damaged.
Making Notes on the Delivery Receipt
If the items and quantity on the delivery receipt match what you received and are undamaged, sign and mark the receipt as "Clear."
If items or boxes are missing, mark the receipt as " Short" and list the missing items. A packing slip will be attached for reference. Allow up to 7 business days for the carrier to find the missing items. If they cannot be located, we will ship replacements to you at no extra charge. If the strip wrap is torn or replaced, mark the receipt as "Wrap Broken."
How Do I Handle a Damaged Shipment?
If any items are damaged, mark the receipt as "Damaged," specifying the items and the nature of the damage. Refuse only the damaged items, keep and sign for the rest, and clearly note the refused items on the receipt. Contact our Customer Service to report which items were refused and which were accepted. We will ship replacements once our Shipping Department confirms the damage with the Freight LTL Company. If you sign for the delivery but later discover damage, you are responsible for it. You will need to contact the Freight LTL Company’s claims department directly to file a claim.