The Goodman 4 Ton 14.3 SEER2 AC & 92% AFUE 100K BTU Gas Furnace System - Upflow, R32 (GLXS4BA4810) combines advanced air conditioning and heating technologies to deliver energy-efficient performance, durability, and year-round comfort.
Key Features of the Goodman 4 Ton 14.3 SEER2 AC:
- Energy-Efficient Compressor: Provides optimal cooling performance while reducing energy costs.
- Pre-Charged Refrigerant: Fully charged for up to 15 feet of tubing for quicker installation.
- Copper Tube with Enhanced Aluminum Fin Coil (5mm): Ensures better heat transfer and long-lasting reliability.
- Factory-Installed Filter Drier: Helps maintain refrigerant purity and system protection.
- High-Pressure Switch: Offers added safety and efficient system operation.
- Extended Life Capacitors: Built for enhanced durability and reduced maintenance.
- Certifications: AHRI Certified and ETL Listed for compliance and performance standards.
Cabinet Design of the Goodman 4 Ton 14.3 SEER2:
- Removable Grille-Style Top: Complies with UL 60335-2-40 and enhances serviceability.
- Architectural Gray Powder-Paint Finish: Provides corrosion resistance with 500-hour salt-spray approval.
- Steel Louver Coil Guard: Protects internal components from damage.
- Top and Side Maintenance Access: Goodman 4 Ton 14.3 SEER2 simplifies service and installation processes.
- Hurricane Compliance: Meets 2023 Florida Building Code for hurricane-type winds (anchor brackets available).
- Multi-Position Installation: Flexible configurations for upflow, horizontal left, or right installations.
- Direct or Non-Direct Venting: Certified for single-pipe or two-pipe venting options.
- Durable Steel Cabinet: Heavy-gauge steel with a robust finish for long-lasting performance.
- Minimal Air Leakage: Qleak less than or equal to 2%, improving efficiency.
- Insulated Heat Exchanger: Fully insulated for noise reduction and better heat retention.
Evaporator Coil - CAPTA6030C3:
- All-Aluminum Construction: Corrosion-resistant design ensures long-lasting durability.
- Optimized for R-32 Refrigerant: Designed specifically for environmentally friendly R-32 refrigerant.
- Thermal Expansion Valves: Factory-installed for enhanced cooling and heat pump efficiency.
- Compact Depth: Additionally, 21-inch depth simplifies attic or tight-space installations.
- Foil-Faced Insulation: Reduces cabinet condensation for cleaner, more efficient operation.
- Rust-Resistant Drain Pan: UV-resistant and designed for low water retention to prevent corrosion.
- Ease of Maintenance: Single front access panel and drain pan rails simplify coil adjustments.
Gas Furnace - GR9S921005CN:
- 92% AFUE Efficiency: Goodman 4 Ton 14.3 SEER2 converts 92% of fuel into usable heat, offering significant energy savings.
- Quiet and Reliable Heating: In addition, it operates with minimal noise for comfortable, efficient warmth.
- Self-Diagnostic Control Board: Constant memory simplifies troubleshooting and ensures consistent performance.
- Lower NOx Emissions: Goodman 4 Ton 14.3 SEER2 reduces environmental impact while maintaining heating efficiency.
- Accessory Compatibility: Lastly, it includes provisions for electronic air cleaner (EAC) and humidifier connections.
In summary, the Goodman 4 Ton 14.3 SEER2 AC & 92% AFUE 100K BTU Gas Furnace System offers an eco-friendly R-32 refrigerant, advanced heating and cooling technologies, and a robust build designed to withstand harsh conditions.
-
AHRI Reference 214860108 AC Model Number GLXS4BA4810 SEER 2 13.8 Tonnage 4 Unit Height x Width x Depth 35.75 x 35.5 x 35.5 in Unit Weight 211 lb Cooling Capacity Nominal 48,000 Btu/H Power Voltage 208/230 V Phase Single Motor Type PSC Min Circuit Amps 25.19 Max Fuse Size 40 Liquid Connection 3/8" Suction Fitting 1-1/8" Refrigerant Type R-32 Evaporator Coil Model Number CAPTA6030C3 Tonnage 5 Unit Height x Width x Depth 30 x 21 x 21 in Unit Weight 66 lb Liquid Connection 3/8" Suction Fitting 7/8" Coil Type Cased Configuration Upflow/Downflow Metering Device TXV Refrigerant Type R-32 Gas Furnace Model Number GR9S921005CN Height x Width x Depth 34.5 x 21 x 28.75 in Weight 141 lb AFEU 92% Configuration Upflow/Horizontal BtuH Input 100,000 BtuH Output 92,100 Tons 3 - 5 CFM 2,000 Min. Circuit Amps 16.7 Vent Size 2" - 3" Motor Type ECM Stages Single LoNox No -
-
Processing Time
We process and ship orders Monday through Friday. Orders placed by 12 p.m. EST on these days are usually shipped within 1 to 2 business days and arrive within 3 to 5 business days. Orders placed on weekends will start processing the next business day. Some items may be backordered, leading to possible delays. Shipping times begin once the order leaves our warehouse. While we aim for timely delivery, delays by freight or ground carriers are beyond our control. FREE Life Gate.
Equipment Arrival
Shipping times are not guaranteed and may vary by address. Upon delivery, inspect each item and match the count with the delivery receipt before signing. Report any missing or incorrect items within 24 hours; claims reported after this period may be denied. Inspect items for damage in front of the driver before signing the receipt. Note any issues like dents or scratches clearly on the receipt or reject the shipment if damaged.
Making Notes on the Delivery Receipt
If the items and quantity on the delivery receipt match what you received and are undamaged, sign and mark the receipt as "Clear."
If items or boxes are missing, mark the receipt as " Short" and list the missing items. A packing slip will be attached for reference. Allow up to 7 business days for the carrier to find the missing items. If they cannot be located, we will ship replacements to you at no extra charge. If the strip wrap is torn or replaced, mark the receipt as "Wrap Broken."
How Do I Handle a Damaged Shipment?
If any items are damaged, mark the receipt as "Damaged," specifying the items and the nature of the damage. Refuse only the damaged items, keep and sign for the rest, and clearly note the refused items on the receipt. Contact our Customer Service to report which items were refused and which were accepted. We will ship replacements once our Shipping Department confirms the damage with the Freight LTL Company. If you sign for the delivery but later discover damage, you are responsible for it. You will need to contact the Freight LTL Company’s claims department directly to file a claim.