The Goodman 4 Ton 14.5 SEER2 AC & 80% AFUE 80K BTU Gas Furnace System - Upflow, R32 (GLXS4BA4810) delivers robust and energy-efficient heating and cooling, making it an ideal choice for residential and light commercial use. Designed for upflow installations, it combines advanced technology, durability, and ease of use for year-round comfort.
Key Benefits of the Goodman 4 Ton 14.5 SEER2 AC:
- Energy-Efficient Compressor: Provides effective cooling while reducing energy consumption.
- Pre-Charged Convenience: Fully charged for up to 15 feet of tubing to simplify installation.
- Durable Coil Design: Copper tubing with enhanced aluminum fins ensures long-lasting performance and efficiency.
- Factory-Installed Components: Goodman 4 Ton 14.5 SEER2 includes a filter drier and extended-life capacitors for reliability and longevity.
- Certified for Quality: In addition, AHRI Certified and ETL Listed, ensuring safety and performance.
Cabinet Features of the Goodman 4 Ton 14.5 SEER2:
- Weather-Resistant Finish: Architectural Gray powder-paint finish withstands up to 500 hours of salt spray for added durability.
- Optimized Airflow: Venturi design enhances air circulation for better cooling efficiency.
- Easy Maintenance: Single-panel access simplifies serviceability and allows space for accessories.
- Storm Ready: Goodman 4 Ton 14.5 SEER2 complies with 2023 Florida Building Code standards for hurricane wind resistance (optional anchor bracket kits available).
Evaporator Coil - CAPTA6030C3:
- All-Aluminum Construction: Corrosion-resistant design enhances reliability and extends coil life.
- R-32 Compatibility: Moreover, it is built to support environmentally friendly R-32 refrigerant with optimized circuits and sensors.
- Thermal Expansion Valves: Pre-installed for seamless operation with cooling and heat pump applications.
- Compact and Accessible: Additionally, 21-inch depth allows for easier attic installations and vertical configurations.
- Leak-Resistant Drain Pan: UV-resistant, rust-proof, and designed to prevent water retention.
Gas Furnace - GR9S800805CN:
- High Reliability: Durable igniter and effective water drainage for dependable operation.
- Quiet and Efficient: Low NOx emissions and energy-efficient circulation provide comfortable heating with minimal noise.
- Self-Diagnostics: Built-in control board with memory simplifies troubleshooting.
- Tax Credit Eligible: Lastly, it meets energy standards for potential government rebates.
Therefore, the Goodman 4 Ton 14.5 SEER2 AC & 80% AFUE 80K BTU Gas Furnace System offers an outstanding combination of efficiency, reliability, and comfort for any modern HVAC requirement.
-
AHRI Reference 214860125 AC Model Number GLXS4BA4810 SEER 2 13.8 Tonnage 4 Unit Height x Width x Depth 35.75 x 35.5 x 35.5 in Unit Weight 211 lb Cooling Capacity Nominal 48,000 Btu/H Power Voltage 208/230 V Phase Single Motor Type PSC Min Circuit Amps 25.19 Max Fuse Size 40 Liquid Connection 3/8" Suction Fitting 1-1/8" Refrigerant Type R-32 Evaporator Coil Model Number CAPTA6030C3 Tonnage 5 Unit Height x Width x Depth 30 x 21 x 21 in Unit Weight 66 lb Liquid Connection 3/8" Suction Fitting 7/8" Coil Type Cased Configuration Upflow/Downflow Metering Device TXV Refrigerant Type R-32 Gas Furnace Model Number GR9S800805CN Height x Width x Depth 33-3/8 x 21 x 28 in Weight 132 lb AFEU 80% Configuration Upflow/Horizontal BtuH Input 80,000 BtuH Output 64,000 Tons 4 CFM 2,000 Min. Circuit Amps 11.3 Motor Type ECM Stages Single LoNox No -
-
Processing Time
We process and ship orders Monday through Friday. Orders placed by 12 p.m. EST on these days are usually shipped within 1 to 2 business days and arrive within 3 to 5 business days. Orders placed on weekends will start processing the next business day. Some items may be backordered, leading to possible delays. Shipping times begin once the order leaves our warehouse. While we aim for timely delivery, delays by freight or ground carriers are beyond our control. FREE Life Gate.
Equipment Arrival
Shipping times are not guaranteed and may vary by address. Upon delivery, inspect each item and match the count with the delivery receipt before signing. Report any missing or incorrect items within 24 hours; claims reported after this period may be denied. Inspect items for damage in front of the driver before signing the receipt. Note any issues like dents or scratches clearly on the receipt or reject the shipment if damaged.
Making Notes on the Delivery Receipt
If the items and quantity on the delivery receipt match what you received and are undamaged, sign and mark the receipt as "Clear."
If items or boxes are missing, mark the receipt as " Short" and list the missing items. A packing slip will be attached for reference. Allow up to 7 business days for the carrier to find the missing items. If they cannot be located, we will ship replacements to you at no extra charge. If the strip wrap is torn or replaced, mark the receipt as "Wrap Broken."
How Do I Handle a Damaged Shipment?
If any items are damaged, mark the receipt as "Damaged," specifying the items and the nature of the damage. Refuse only the damaged items, keep and sign for the rest, and clearly note the refused items on the receipt. Contact our Customer Service to report which items were refused and which were accepted. We will ship replacements once our Shipping Department confirms the damage with the Freight LTL Company. If you sign for the delivery but later discover damage, you are responsible for it. You will need to contact the Freight LTL Company’s claims department directly to file a claim.