The Goodman 5 Ton 14 SEER2 AC & 80% AFUE 80K BTU Gas Furnace System - Upflow, R32 is a reliable solution for year-round comfort, offering both efficient cooling and heating. It combines high performance with energy savings, providing reliable operation throughout the year.
Key Features of the Goodman 5 Ton 14 SEER2 AC:
- Energy-Efficient Compressor: Reduces electricity use while delivering strong cooling performance.
- Fully Charged for 15' of Tubing: Simplifies installation.
- Copper Tube/Enhanced Aluminum Coil: Improved heat exchange and durability.
- Factory-Installed Filter Drier & Easy Access Service Valves: Protects the system and simplifies maintenance.
- High-Pressure Switch & Extended Life Capacitors: Enhances system reliability.
- AHRI Certified & ETL Listed: Meets industry standards.
Cabinet Features of the Goodman 5 Ton 14 SEER2:
- Removable Grille-Style Top Design: Compliant with safety standards.
- Venturi Design for Increased Airflow: Boosts efficiency.
- Architectural Gray Finish & Steel Louver Coil Guard: Durable and corrosion-resistant.
- Top & Side Maintenance Access: Easy servicing.
- Hurricane-Ready: Goodman 5 Ton 14 SEER2 meets Florida Building Code for wind integrity.
Evaporator Coil - CAPTA6030C3:
- All-Aluminum Coil: Durable and corrosion-resistant.
- Optimized for R-32 Refrigerant: Environmentally friendly.
- Thermal Expansion Valves: Ensures proper refrigerant control.
- Foil-Faced Insulation & UV-Resistant Drain Pan: Reduces condensation and improves drainage.
Gas Furnace - GR9S800805CN:
- 80% AFUE Efficiency: Reduces heating costs.
- Durable Igniter & Low NOx Emissions: Quiet, reliable, and eco-friendly operation.
- Self-Diagnostic Control Board: Also, it simplifies troubleshooting.
- Tax Credit Eligible: Meets requirements for tax savings.
- Dual Thermostat Compatibility: Lastly, it works with single and two-stage thermostats.
Therefore, the Goodman 5 Ton 14 SEER2 AC & 80% AFUE 80K BTU Gas Furnace System is a high-performance, energy-efficient solution for cooling and heating. Overall, it’s built for reliability and efficiency, providing year-round comfort with minimal maintenance
-
AHRI Reference 214860185 AC Model Number GLXS4BA6010 SEER 2 13.8 Tonnage 5 Unit Height x Width x Depth 39.5 x 35.5 x 35.5 in Unit Weight 224 lb Cooling Capacity Nominal 60,000 Btu/H Power Voltage 208/230 V Phase Single Motor Type PSC Min Circuit Amps 32.44 Max Fuse Size 50 Liquid Connection 3/8" Suction Fitting 1-1/8" Refrigerant Type R-32 Evaporator Coil Model Number CAPTA6030C3 Tonnage 5 Unit Height x Width x Depth 30 x 21 x 21 in Unit Weight 66 lb Liquid Connection 3/8" Suction Fitting 7/8" Coil Type Cased Configuration Upflow/Downflow Metering Device TXV Refrigerant Type R-32 Gas Furnace Model Number GR9S800805CN Height x Width x Depth 33-3/8 x 21 x 28 in Weight 132 lb AFEU 80% Configuration Upflow/Horizontal BtuH Input 80,000 BtuH Output 64,000 Tons 4 CFM 2,000 Min. Circuit Amps 11.3 Motor Type ECM Stages Single LoNox No -
-
Processing Time
We process and ship orders Monday through Friday. Orders placed by 12 p.m. EST on these days are usually shipped within 1 to 2 business days and arrive within 3 to 5 business days. Orders placed on weekends will start processing the next business day. Some items may be backordered, leading to possible delays. Shipping times begin once the order leaves our warehouse. While we aim for timely delivery, delays by freight or ground carriers are beyond our control. FREE Life Gate.
Equipment Arrival
Shipping times are not guaranteed and may vary by address. Upon delivery, inspect each item and match the count with the delivery receipt before signing. Report any missing or incorrect items within 24 hours; claims reported after this period may be denied. Inspect items for damage in front of the driver before signing the receipt. Note any issues like dents or scratches clearly on the receipt or reject the shipment if damaged.
Making Notes on the Delivery Receipt
If the items and quantity on the delivery receipt match what you received and are undamaged, sign and mark the receipt as "Clear."
If items or boxes are missing, mark the receipt as " Short" and list the missing items. A packing slip will be attached for reference. Allow up to 7 business days for the carrier to find the missing items. If they cannot be located, we will ship replacements to you at no extra charge. If the strip wrap is torn or replaced, mark the receipt as "Wrap Broken."
How Do I Handle a Damaged Shipment?
If any items are damaged, mark the receipt as "Damaged," specifying the items and the nature of the damage. Refuse only the damaged items, keep and sign for the rest, and clearly note the refused items on the receipt. Contact our Customer Service to report which items were refused and which were accepted. We will ship replacements once our Shipping Department confirms the damage with the Freight LTL Company. If you sign for the delivery but later discover damage, you are responsible for it. You will need to contact the Freight LTL Company’s claims department directly to file a claim.